10 Ways We Prove Your Device Actually Works

Functional and Performance Testing for medical device programs at our Oragadam laboratory — torque, connection strength, burst, flow rate, and fatigue evaluation referenced to ISO 10993-7:2026 and device-specific ISO methods.

Call 90876 86986 WhatsApp Us

A device that passes every material and biocompatibility check can still fail the moment it’s actually used.

Functional and Performance Testing for medical device programs is the checkpoint that answers a question no chemistry report can: does the device do what it’s meant to do, reliably, under the forces and cycles it will actually see in a hospital, a clinic, or a patient’s home. Our Functional and Performance Testing for medical device service at the Oragadam laboratory covers ten checkpoints across mechanical function, connection integrity, and repeated-use durability, referenced to ISO 10993-7:2026 alongside the device-specific ISO and ASTM standards each checkpoint depends on.

Device-specific functional testing is where every study starts — the checkpoint built around the exact standard your device category calls for, whether that’s a syringe, a catheter, an infusion set, or a surgical instrument, so the study answers the question a reviewer will actually ask rather than a generic one. Connection strength testing for medical device luer fittings, tubing sets, and hub interfaces confirms a connection stays sealed under the pull and torque forces it will meet in real use; a connection that separates mid-procedure is not a packaging defect, it’s a functional failure, and it gets caught here. Burst testing pressurizes bags, tubing, and sealed assemblies past their rated limit to confirm the margin between normal use and failure is real, not assumed. Flow rate testing verifies that infusion sets, catheters, and fluid-path devices deliver within their labelled tolerance, because a flow rate that drifts outside spec is a dosing problem before it’s anything else.

This checkpoint measures the rotational force a connector, cap, or fitting can withstand before it slips or fails, and it runs as three separate checks across most device families — assembly torque, in-use torque, and post-cycling torque — because a fitting that holds on day one can still loosen after repeated handling. Pull-out force testing quantifies how much axial force it takes to separate a needle, a catheter hub, or a bonded joint, directly informing the safety margin a clinician relies on without thinking about it. Activation force testing covers auto-injectors, safety needles, and spring-loaded mechanisms, confirming the force needed to activate the device sits inside the range a real patient or clinician can reliably apply.

Repeated-use cycles testing simulates the full lifecycle a reusable device is rated for — hundreds or thousands of open-close, insert-withdraw, or actuate cycles — to confirm performance doesn’t degrade before the labelled reuse count is reached. Fatigue and device-specific functional testing closes the loop: fatigue testing applies cyclic mechanical stress to detect crack initiation or fracture long before it would show up in the field, while the device-specific check confirms the whole assembly still performs against its original functional spec after that stress. Pressure testing rounds out the programme for pressure-rated components, catheters, and connectors, confirming the device holds its rated pressure without leak or deformation. Manufacturers bring their programs to Kiyo R&D Lab because a single missed checkpoint in Medical Device Testing doesn’t just fail an audit — it fails in someone’s hands. Running all ten checkpoints under one accredited scope at Oragadam, with reports formatted for direct regulatory submission, is what turns a Functional and Performance Testing for medical device study from a compliance formality into evidence your quality team can actually stand behind.

PERFORMANCE & FUNCTIONAL EVALUATION

Ten Accredited Functional Checkpoints

Referenced to ISO 10993-7:2026 and device-specific ISO / ASTM methods

Device-specific functional testing under microscope inspection
01

Device-Specific Functional Testing

Applicable device-category ISO standard

Connection strength testing fixture and grips
02

Connection Strength Testing

ISO 80369 · ISO 594-1/-2

Burst testing of sealed medical device bag under pressure
03

Burst Testing

ASTM F2054 · ISO 594

Flow rate testing torque wheel apparatus
04

Flow Rate Testing

ISO 8536 · IEC 60601-2-24

Torque testing rig for medical device fittings
05

Torque Testing

ISO 80369-7 · In-house method

Pull-out force testing on needle hub assembly
06

Pull-Out Force Testing

ISO 11040-4 · ASTM F88

Activation force testing on spring-loaded safety device
07

Activation Force Testing

ISO 11608 · In-house method

Repeated-use cycles testing on reusable surgical instruments
08

Repeated-Use Cycles Testing

ISO 17664-1 · In-house method

Fatigue testing rig applying cyclic mechanical stress
09

Fatigue Testing

ISO 25539 · ASTM F2477

Pressure testing on ventilator and fluid-path device
10

Pressure Testing

ISO 10555 · IEC 60601-1

How Our Functional Testing Process Works

Four steps, from device intake to a validated report

1

Device Intake

Device or component received under chain-of-custody against your target standard.

2

Baseline Function

Connection, flow, and torque checks establish the as-built performance baseline.

3

Cycling & Stress

Repeated-use, fatigue, and pressure loading run to the rated lifecycle.

4

Certified Report

Delivered digitally, ready for your validation file.

Standards Behind Our Medical Device Testing

CHECKPOINT SCOPE STANDARD
Connection StrengthLuer, hub & tubing joint integrityISO 80369, ISO 594-1/-2
Torque TestingAssembly, in-use & post-cycling torqueISO 80369-7
Fatigue TestingCyclic stress, crack & fracture detectionISO 25539, ASTM F2477
Pressure & Burst TestingRated pressure, leak & deformation limitsISO 10555, ASTM F2054
VISIT OUR LABORATORY

Kiyo R&D Lab – Oragadam

Our functional and performance testing suite is based at No.13, Srinivasa Perumal Street, Panapakkam, Serapanacheri, Greater Chennai, Tamil Nadu 601301.

Frequently Asked Questions

What does Functional and Performance Testing for medical device cover? +

It covers ten checkpoints — connection strength, burst, flow rate, torque, pull-out force, activation force, repeated-use cycles, fatigue, and device-specific functional testing, and pressure — referenced to ISO 10993-7:2026 and the applicable device-category standard.

Why is torque testing run at three different stages? +

A fitting that holds on day one can still loosen after handling, so this checkpoint is measured on assembly, again after in-use handling, and once more after repeated cycling to confirm the connection stays reliable through its full life.

How does connection strength testing for medical device fittings differ from pull-out force testing? +

Connection strength testing looks at the whole joint under combined pull, torque, and pressure loading, while pull-out force testing isolates the axial force needed to separate a single component such as a needle or hub.

Do fatigue and device-specific functional testing always run together? +

For most repeated-use or cyclic-load devices, yes — the cyclic stress checkpoint confirms the part doesn’t crack or fracture, and the device-category check then confirms the whole assembly still meets its original functional spec after that stress.

How do I get a quote for this testing? +

Call us at 90876 86986, message us on WhatsApp, or fill in the enquiry form below with your device and testing needs.

Book Your Functional and Performance Testing for Medical Device Today

Talk to our Oragadam engineering team about torque, connection strength, fatigue, or full-lifecycle studies for your Medical Device Testing programme.