Our material characterization service covers eight techniques run at our Oragadam laboratory, giving medical device manufacturers thermal, structural, and compositional data on their polymers. This polymer analysis sits alongside our medical device material testing capabilities, so a manufacturer gets both the mechanical performance and the underlying material science behind it, in one place.
Eight Polymer Analysis Techniques
Material characterization run to ASTM and ISO standards
Polymer ID by FTIR
ASTM E1252
DSC Thermal Analysis
ASTM D3418, ISO 11357
Glass Transition Temp.
ASTM D3418, ISO 11357
Melting Point Analysis
ASTM D3418, ISO 11357
TGA Decomposition
ASTM E1131, ISO 11358
Filler Content (TGA)
ASTM E1131, ISO 11358
Crystallinity Analysis
In-house method
SEM EDS Analysis
In-house method
How Our Testing Process Works
Four steps, from sample to certified report
Sample Intake
Logged at our Oragadam facility with a unique reference ID.
Technique Selection
The right instrumentation chosen for your material’s chemistry.
Instrumental Analysis
Run on calibrated thermal and spectroscopic instrumentation.
Certified Report
Delivered digitally, ready for your QA documentation.
Standards Behind Our Testing
| TECHNIQUE | WHAT IT CONFIRMS | STANDARD |
|---|---|---|
| Infrared Spectroscopy (Polymer ID) | Polymer identity by infrared spectrum | ASTM E1252 |
| DSC (Melting Point / Tg) | Thermal transition temperatures | ASTM D3418 / ISO 11357 |
| TGA (Decomposition / Filler) | Compositional and thermal stability data | ASTM E1131 / ISO 11358 |
| Crystallinity / Elemental Composition | Structural and elemental composition | IN-HOUSE |
Kiyo R&D Lab – Oragadam
Our Oragadam facility is based at No.13, Srinivasa Perumal Street, Panapakkam, Serapanacheri, Greater Chennai, Tamil Nadu 601301.
Frequently Asked Questions
What does material characterization actually tell me? +
This service identifies what a polymer is, how it behaves under heat, and what’s inside it — through thermal, spectroscopic, and elemental techniques.
What’s the difference between DSC and thermogravimetric testing? +
DSC measures thermal transitions like melting point and glass transition temperature. Thermogravimetric analysis tracks weight loss as a sample is heated, revealing decomposition behavior and filler content.
Can infrared spectroscopy confirm a polymer’s identity? +
Yes. This technique generates an infrared spectrum unique to a polymer’s chemical structure, referenced to ASTM E1252 for confirming identity.
What is the turnaround time for this testing? +
Turnaround depends on which techniques are required. Contact us with your material and sample details for an exact timeline.
How do I get a quote for this testing? +
Call us at 90876 86986, message us on WhatsApp, or fill in the enquiry form below with your material details and required techniques.
Related Medical Device Testing Services
Get Your Polymer Characterized
Talk to our Oragadam lab team about testing your device’s polymer.
Call 90876 86986 WhatsApp UsRequest Material Characterization
Fill in your details below and our team will get back to you shortly.